Gas & Liquid Metering Skid
Flow Metering System | Sư Tử Nâu Platform
YEAR: 2015-2016
LOCATION: Sư Tử Nâu platform, offshore Vietnam
SCOPE OF WORK
Design, fabrication, installation & commissioning Allocation Flow Metering System for:
Gas Metering: Flowrate 24.046 ~ 37.429 MMSCFD (Min. ~ Max.) with Flowsic Ultrasonic Flowmeter
Oil Metering: Flowrate 2051 ~ 50147 USBPD (Min. ~ Max.) with Coriolis Flow Meter Emerson Micro Motion
Produced Water: Flowrate 34.26 ~ 131.5 m3/h (Min. ~ Max.) with Emerson Daniel Turbine Flow Meter
Sampling System with Jiskoot withdrawable ByScoop
Flow Computer Emerson Floboss
LOCATION: Sư Tử Nâu platform, offshore Vietnam
SCOPE OF WORK
Design, fabrication, installation & commissioning Allocation Flow Metering System for:
Gas Metering: Flowrate 24.046 ~ 37.429 MMSCFD (Min. ~ Max.) with Flowsic Ultrasonic Flowmeter
Oil Metering: Flowrate 2051 ~ 50147 USBPD (Min. ~ Max.) with Coriolis Flow Meter Emerson Micro Motion
Produced Water: Flowrate 34.26 ~ 131.5 m3/h (Min. ~ Max.) with Emerson Daniel Turbine Flow Meter
Sampling System with Jiskoot withdrawable ByScoop
Flow Computer Emerson Floboss
Interested in this project?
Contact us for more information, pricing, or technical specifications.
Contact Us